Case Study

Centrifugal Pump Volute — CF8 Investment Casting and Pressure Verification

A pump casing for the project-specified ambient-temperature clean-water and mildly corrosive service. This CF8 stainless steel volute forms the casing of a centrifugal pump.

October 12, 20263 min read
CF8 centrifugal pump volute showing two flanged external connections

Product: Centrifugal-pump volute / pump casing
Application: Fluid-handling equipment for ambient-temperature clean water and mildly corrosive service
Material: CF8 cast stainless steel under ASTM A351
Process: Investment casting (lost-wax casting), followed by project-specific machining and inspection

Product and application

A pump casing for the project-specified ambient-temperature clean-water and mildly corrosive service.

Project problem and requirements

This CF8 stainless steel volute forms the casing of a centrifugal pump. The project drawing called for controlled flange interfaces, a formed internal passage and consistent machining allowance on the sealing and mounting features. The specified service involved ambient-temperature clean water and mildly corrosive conditions.

Second view of pump volute opening and flanged connection
Another exterior view of the volute and flange arrangement.

Solution and manufacturing approach

The curved cavity and changes in wall thickness made core position and shrinkage control important. During sampling, a local wall-thickness deviation led to changes in the wax tooling and water-soluble core location. Radiographic review found isolated shrinkage near a volute corner, and two samples showed minor leakage during hydrostatic testing. The project team revised the gating and feeding arrangement before repeat production.

Representative illustration of exterior flanges and volute housing
Representative illustration / 示意图. Exterior areas only; not an actual drawing, measurement or test record.

Verification and outcome

The inspection route included heat-level material checks, first-article dimensional measurement, penetrant testing and hydrostatic testing of every production casing. The specified hydrostatic test was 1.65 MPa for 10 minutes; accepted parts showed no visible leakage. The first-article dimensional report was submitted for review, and the project progressed from sample confirmation through a small production run into repeat supply. For general process considerations, see our pump and valve investment-casting guide.

Engineering review

Discuss your component with Tianlu

Share the drawing, alloy, annual volume and inspection requirements for an engineering review.

Request a Quote ›